ft. Specifier Select Option Dampers shall be equipped with factory installed damper position indication switch package. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. Enter your email and join our mailing listDesigned for isolation and containment of the airstream, Ruskin bubble tight industrial dampers for round or rectangular air paths will meet or exceed bubble tight leakage requirements in conformance with AMCA Standard 500D and are available with factory-supplied and mounted actuation. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. ©Ruskin 2000 3900 Dr. 25" w. g. Availability: Get a Quote. Maximum Damper Width (A Dimension) Maximum Damper Width (A Dimension) AREA FACTOR TABLE EXAMPLE: 1. Greaves Rd ansas City, O 600 P: 16 761-776 F 16 765-55 E ruskinruskin. From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control damper. The CFD2 is a UL555C Classified Ceiling Fire Damper. LEADS; TDP05K Placement Tool; Windload Calculator; Resources. A 1" (25) diameter jackshaft is normally used. Ruskin. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. With Seals Dampers 40" (1016) and under – 2 pieces of 18 gage steel. 4) steel. Masonry/Wall or Floor: #10 self-tapping concrete screws. The CFD7 is UL555C Classified Ceiling Fire Damper for wood construction. Ruskin July 2020 Page1 CD60DC (DATA CENTER) High-performance Galvanized Steel Airfoil Blade Damper AMCA Class IA Leakage Rated The CD60DC is designed for HVAC systems serving data center facilities where high performance and reliability is expected. The majority of designs are rated at 2 or 3 hours. of damper with minimum of 20 in. MAXIMUM SIZE Single section Vertical Installation DIBD2 - 32"w x 36"h (813 x 914). All (D)IBD Curtain Type Fire Dampers Excluding IBDT Series model – FLIB fd fuse link assembly 1. The factory mounted fast-acting 8-second spring open actuatorprovides optimal performance and reliability. ft. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. Louver blades are . The CD40x2 has an 8" frame and aluminum construction. Model ‘G’ curtain fire dampers are offset. 3. would require CD50 damper with maximum section width of 36" (914). Aluminum Airfoil Blades. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec - ommended maximums. cealed in the frame. , Ruskin does not recommend using these designs in systems with velocities greater than 2000 fpm. Figure 5. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. 5hr Static Fire Dampers » 3hr Static. Specifier Select Options. Wood/Steel Stud Wall: #10 screws b. Ruskin UL listed solutions are available. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and and. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. Space fasteners 6" (152) on center and a maximum 2" (51) from the ends of the joining sec-tions or from each corner. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. Unlike conventional mounting angles that can-not be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners)- Single section dampers ordered with either 12” (305), 14” (356) or 16” (406) long sleeve; the IBD20, 40, 60, 230, 430 and 630 models may be substituted. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. 7447 Toll Free: 800. 2. When used in fan discharge applications, damper should be the damper frame. (Consult for electronic version of this “Quick” spec as well as for complete 3-part CSI MasterFormat Specifications)Ruskin model ABD offers HVAC design engineers an automatic balancing damper which provides: • Energy savings to building owner • Constant maintained airflow volume • Good indoor air quality • Anti-microbial agent prohibiting bacteria or mold growth • Easy installation; requires no tool for adjustment. Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides; • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance. Ruskin CD30AF1/CD30AF2 con-trol dampers. The CDRS15 is a true round commercial control damper that installs easily in round spiral ductwork. back pressure depending on damper size. cheng@jci. We always proudly labeled our literature with the AMCA Certified Ratings Logo and now we will be labeling on dampers as well. It features: Airfoil blades, which have greater strength, less static pressure, superior sealing ability, superior fire protection ability and produce less noise. 6) 304tested and classified Ceiling Dampers (also called Ceiling Fire Dampers or Radiation Dampers) to provide fire and heat protection where HVAC components penetrate the ceiling membrane. It features: Low leakage. 765. If the actuator must be mounted on top or bottom, select the FSD60V. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. g. R8039)<o:p></o:p> Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Curtain type. Life Safety » Combination Fire/Smoke Dampers 1. Automatic Balancing Dampers. Learn more about the features, specifications and dimensions of the PVC12 damper from Ruskin, the leading manufacturer of air control. II. lbs. Dampers Corridor Dampers Fire Dampers Smoke Dampers Ruskin® 3900 Dr. • Airfoil High Performance Dampers • Triple-V Standard Performance Dampers • Ruskin Exclusive True Round Dampers • Ruskin Fast Mounting Angles • Complete Corridor. g. S3G Back Draft Damper Product Data/Submittal Author: Ruskin Authority in Air Control - Subject: Ruskin s S3G Commercial backdraft damper has a 3" (76) frame and is constructed of galvanized steel. Dampers shall be in all respects equivalent to Ruskin model IL35. Ruskin FAST and PFMA are 20 gauge steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. Dampers shall be in all respects equivalent to Ruskin model CBD6. II-FSD36-0121/ Replaces II-FSD36-514 ©Ruskin January 2021 ® APPLICATION The FSD35, FSD36 and FSD37 are combination fire and smoke dampers designed to restrict the passage of flame and resist the passage of smoke. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. Greaves Rd. back pressure depending on damper size. 3 (damper installed with duct upstream and downstream). Actuators enable a damper to operate with controlled positioning throughout the stroke of the damper. We service the Mechanical Contractor and Mechanical Engineering community in Southern California. MODEL 914 SUGGESTED SPECIFICATION Suggested specification for Model 914 Ruskin Swartwout Fiber-glass Series round dampers (revision 6394). Rusin anuary 2021 Replaces Spec AIRFLOW-IQ-01 Pae 4 High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. Examples include: industrial. the following control damper models: CD50 CD504 CD40 CD403 CD51 T-Flange frame is available at additional cost for the following Ruskin commercial control damper models: CD60 CD36 CD356 IL35 CD35 CD355 MINIMUM SIZE Models CD50, CD504, CD60, CD356 and CD355, 6" x 4" (152 x 102). The Ruskin backdraft damper model CBDR92 is designed to prevent backflow in high velocity HVAC and industrial process systems. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. Offset single blade design lets Ruskin engineers calibrate the damper operation to exact customer specification. For the name and address of your Ruskin Representative, call (816) 761-7476, or visit our web site at Ruskin can engineer and install pneumatic, electric or manual type actuation to best meet your specifications. lbs. com. • For proper operation, damper must be installed square and free from racking. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. Hexagonal axles that ensure a positive lock with blades. Single Blades. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (3) steel rivets or 1/2" (13) long welds. (1 kPa). INSTALLATION CD355 SERIES DAMPER IS NOT RECOMMENDED FOR INSTAL- Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. lbs. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. The PVC12 damper is a corrosion-resistant and low-maintenance device that can regulate air flow in ducts or pipes. Providing accurate control or isolation of. 25" w. Face and by-pass. Ruskin (Thailand) Co. angles together at corners of dampers. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. Pressure drop and free area may vary. Maximum rating of 2,000 fpm and 4" w. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. 1. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood True Round Grille or through ceiling membrane penetrationRuskin February 222 Page 1 FDR25 Galvanized Steel True Round Fire Damper 1 1/2 Hour UL555 Rating for use in Dynamic & Static Systems Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and collection systems. 2. Kansas City, MO 64030Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. Each has added features that enable them to meet all high temperature, high pressure airflow. It features: UL555S Class I leakage class. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Ruskin model SD50 offers HVAC design engineers an ultra-low leak high performance Leakage Class I smoke damper which provides: • Barrier to stop smoke • Lowest pressure drop for energy savings • Optional fail open operation for smoke exhaust applications • Highest dynamic closure rating of 4,000fpm & 8” static pressure. These models combine the strength of stainless steel and the protection of anodized aluminum to combat salt water elements. Speak With a Technical Expert. Conservative ratings are pre - sented intentionally in an effort to avoid misapplication. The FSDR60 is a "true round" Class 1 leakage rated combination fire and smoke damper designed for use in metal, wood or concrete fire and smoke rated partitions and concrete floors. Each has added features that enable them to meet all high temperature, high pressure. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. g. This damper has insulated extruded aluminum blades with a thermal break and twin blade edge seals that ensure low leakage and reliable performance. 8) steel. “Out Of Wall” Grille Access Fire Dampers 1 1/2 Hour UL555 Rated | For Dynamic & Static Systems DIBD2GA are dynamic fire dampers designed for “out of wall” applications. Available with factory furnished sleeves. Ruskin Literature. It features: Corrosion resistant backdraft protection from its stainless steel construction. Each has added features that enable them to meet all high temperature, high pressure airflow. Installation Instructions FSD60FA, FSD36FA, and FSD60FA-M Front Access Combination Fire & Smoke Damper 11/2 HOUR UL555 & UL555S CLASS I OR CLASS II CLASSIFIED RATING Author: Ruskin - Dampers Louvers (816) 761-7476 Subject: Models FSD60FA, FSD60FA-M, and FSD36FA combination fire/ smoke dampers are. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. Torque applied holding damper closed at 10 in. The damper is rated for maximum velocity of 2,000 fpm (10. GRANDVIEW, Mo. Every damper is built with performance in mind and tested per AMCA standards in Ruskin's Laboratory. BIM allows for intelligent, 3D and parametric object-based design and provides full bi-directional associativity. TION 1. It features: AMCA Class 1A leakage for energy savings R value – 2. FILES (0) Share this page: Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and. upstream of the damper. Greaves Rd. They are designed to be installed inside duct work rather than flange mounted. 3. Stainless Steel Construction See model (D)IBD2SS. 5, CFD4 and CFD(R)5 are UL labeled ceiling radiation dampers. When used in fan discharge applications, damper should bethe damper frame. Home; PRODUCTS Air Control and Backdraft Dampers Ceiling Radiation Dampers. 125" (3. UL555S rating up to 350°F (177°C). emergency, dampers and their actuators alike may be required to operate at elevated temperatures. The TDP05K is capable of measuring a velocity range from Oto 5,000 FPM and displaying the flow and temperature. Maximum rating of 4,000 fpm and 4" w. It is recommended for heavy duty applications using multi-section dampers where either unison or sequence operation is required. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowSun Control Sunshades. 3. Models are designed for medium to high pressure applications and can be provided with manual control devices or factory installed electronic or pneumatic actuators. com . Every damper is built with performance in mind and tested per AMCA standards. Built from strong materials and designed on state-of-the-art. (Consult for electronic version of this “Quick” spec as well as for complete 3- part CSI MasterFormat Specifications) Document Title Limited Warranty Document LINKS TO IMPORTANT DOCUMENTSFire and Smoke Dampers Ruskin actionair ES Series Operating And Maintenance Manual. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. 248 Kpa) tested per AMCA 500. 3 (damper installed with duct upstream and downstream). The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. Galvanized Steel V-Groove Blades. Damper shall be Ruskin model CDRS82. The damper is rated for Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Determine area factor for damper by entering the Area Factor Table through duct width and height. It features: Vertical blades. a. 5. • Sealing durability in. Dampers shall be designed for maximum 1500 fpm spot velocities and up to 4" w. w. 1. used in conjunction with Ruskin fire/smoke dampers. The. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. ,Application The No. 01" w. Must be installed in the factory. It features a galvanized steel frame, single skin blades, and a variety of actuator options. Zone Control Systems. Our plant in Thailand is well-equipped to manufacture next-generation products. 4 inches w. UL approval for dual directional airflow. (Dampers with V-Groove blades are structurally designed for velocities to 2000 FPM and above. Masonry/Wall or Floor: #10 self-tapping concrete screws. Spec vFBD35-818/Replaces VFBD35-708 ©Ruskin August 2018 • 3900 Dr. Mounting angles must overlap the partition a minimum of 1" (25). Ruskin Literature. The AiQ-TD-50 offers accurate airflow measurement and control through electronicthermal dispersion technology utilized in Ruskin model TDP05K Airflow & Temperature Measuring probes(s) with the inclusion of Ruskin model CD50 control damper factory configured as one compact assembly. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. 761. dampers. Access doors provide an easy means of reaching damper components inside the ductwork. g. Unequal section sizes. It features a galvanized steel frame, single skin blades, and a variety of actuator options. The CBDR82 damper blade willRuskin is pleased to announce the availability of Revit® 3-D files of select products. The CD60CE is designed for coastal regions and other corrosive environments such as salt-water regions. FILES (0) Share this page: Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Damper – Ruskin fire or fire/leakage rated damper in minimum 20 gage (1. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). The FSD60FA da mper may be installed. 7476 Fax: 816. The FSD60 can be installed in horizontal or vertical applications and has low leakage and pressure drop ratings. L501). FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERSLeading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. 7476 Fax: 816. Ceiling Fire Dampers UL Classified Radiation Dampers for Wood Joist Construction The CFD7 is a UL Classified Ceiling Fire Damper that is UL approved for installation in ceilings constructed from wood joists. lbs. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. DAMPER SIZES Understanding damper leakage rates and leakage classes enables specifiers, contractors, and building owners to identify the correct damper products. N474 Features • High-temperature rated drive system • Reversible fail-safe spring returnRuskin CD36 is available at competitive price! CD36 Commercial Control Dampers Type at $1. M. 24VAC modulating actuators (spring return or fail-in-place) can. (25) sp. CFD7T - 2"x4" Truss Assemblies (Ref. Consult Ruskin or your Ruskin representative when damper is to be. The airfoil blades are designed for HVAC systems with velocity and pressures up to 4,000 fpm and 8" w. Shims should be used between damper frame and opening or duct to. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. g. Commercial Control Damper CD60. 081" thick extruded aluminum at approximately 4" c-c spacing. 75" w. static pressure. 025” thick formed aluminum with concealed blade linkage, synthetic bearings. Most F/Cs andSMOKE & COMBINATION FIRE SMOKE DAMPER ACTUATORS. Standard, 1 1/2 and 3 hr. Ruskin manufactures an extensive line of UL rated and listed dampers to protect life and mitigate property loss during a life safety event. It features: Extremely low leakage. FSD35. Enter the Pressure Drop Chart at the determined area factor. All data has been. Learn about their history, products,. 5 illustrates a plenum mounted damper. Ruskin model TED50XT offers HVAC design engineers an ultra-low leak thermally efficient damper which provides: • Energy savings for building owners • Effective resistance to condensation in climate prone areas. Curtain Type Static Fire Dampers 1 1/2 Hour UL555 Rated For Use In Static System Ruskin Model IBD20, 40, and 60 are 1 1/2 hour UL classified static (fans off) curtain style fire dampers for use in HVAC systems that shut down during a fire event. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. static pressure. The blades are the same thickness throughout the shape, optimizing the R-Value rating. Ruskin Fire/Smoke Dampers. They are easy to install, easy to use, and are customizable to the needs of any building automation system. A change anywhere is a change everywhere, instantly!2. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. damper section width as indicated. Relief doors open automatically to prevent ductwork from imploding or exploding due to differential pressure. Constructed with durable galvanized steel. Aluminum Airfoil Blades. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. 2 m/s) and 4” w. UL 555/555S 1. The CDR82 Round Control Damper features: Accurate airflow control within round ductwork systems in medium pressure industrial HVAC systems Desired performance easily attained in pressure differentials of 6"w. So turn “on” to energy savings while your building is“off” and let Ruskin start saving you money today. g. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. g. or N. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. Dampers shall be Ruskin model FSDR25. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. Damper Width “A” Dimension in inches (mm)Round Control Damper Class 1A Leakage The CDRS25 “true round” control damper is designed for low to medium pressure and. Furnish and install, at locations shown on plans or in accordance with schedules, counterbalance backdraft dampers that meet the following minimum construction standards: frame shall be (specify). Ruskin Literature. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. The damper/actuator assembly is exposed to elevated temperatures for 30 minutes and then immediately cycled three times. g. The Ruskin optional firestopping installation is one of our latest installation instruction supplements we offer. AUTHORITY IN AIR CONTROL The (D)IBD20G meets the requirements for fire dampers established by: National Fire Protection Association NFPA Standards 90A and 101 ICC International Building Codes CSFM California State Fire Marshal Fire Damper Listing (#3225. (2 kPa). Damper shall be equivalent to Ruskin model ARD25. angles together at corners of dampers. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade turnsA. 6 psi to 44. NOTES: 1. g. Standard features vary by model to make application selection straightforward. Multi-section dampers typically use jackshafts to link sections together. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. Axles that positively lock to blades without screws or welds. Axles shall be square or hexagonal positively locked into the damper blade. Galvanized Steel Airfoil Blades. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. SUGGESTED SPECIFICATION • When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. Damper shall be, in all respects, equivalent to Ruskin model BD2A2. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. to. Leakage ratings are based on AmCA Standard 500 using Test Setup Apparatus Figure 5. Damper shall be Ruskin model BTR82. Model CFM Static Pressure Throw In Feet Neck Velocity Jet Velocity Noise Level. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. 2 m/s) and 4” w. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. , N. 1. The switch package shall include two position indicator switches linked directly to the damper blade to provide full open and full closed damper blade position. Learn more about the FSD60 and its installation instructions from this document. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. The damper ships with a factory mounted and commissioned 24 VAC, spring return actuator set to power closed and spring or "fail" open. Louvers & Architectural. Our History. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. (0. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Fiberglass Backdraft Dampers. NOTE: Dampers may tolerate higher pressures and velocities than those listed here. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. g. Dampers shall incorporate a dish-shaped circular blade mounted to internal slide-Ruskin CD450 is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Fire dampers with 11/2 or 3 hour ratings for walls or floors are not to be used in fire rated ceiling openings. Dampers shall be Ruskin CD60 model. Specifier Select Option Dampers shall be equipped with factory installed damper. a. The damper is rated for5 82w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. 3. The SD60M is a UL555S Classified Leakage Class I modulating smoke damper. Louver and Architectural Solutions. The operable blades are opened and closed manually, or with the use of an actuator. We offer a wide variety of products to mee. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Refer to the UL approved installation instructions for specific requirements. Concealed linkage out of the airstream for low maintenance and reduced air turbulence. For damper styles WR, WC, WO and BC only the duct connection portion extends through the wall and the damper. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). consider an airfoil blade damper, such as Ruskin model CD60. Ruskin Literature. a.